Friday, April 8, 2011

·        How many parking spaces are required for the Keystone Library? Show your calculation. (COO Table 9, Section 159.142 or UDO Table 10.0.3.B)
1 per 300sq feet. The library is 9348sq feet. So I took 9348 divided by 300 and got 32 parking spaces.
·        What distance must parking lots be set back from the property line? ((UDO Section 4.B.1)
Set back 20 feet
·        Assuming a 90 degree parking angle, what size parking spaces should be used? (COO Table 10, Section 159.143 or UDO Table 10.0.4.A)
9 feet by 18 feet
·        What aisle width should be used? (COO Table 10, Section 159.143 or UDO Table 10.0.4.A)
24 feet
·        Describe the requirements on driveway (ingress and egress) location from adjacent property lines and intersections. (COO Section 159.143 or UDO Section 4.C.2)
 Non-residential driveway entrances or exits shall be at least 25 feet from an adjoining residential property line; ten feet from an adjoining non-residential property line; or 45 feet from an intersection.
·        What is the maximum driveway width that can be used for a non-residential development? (COO Section 159.143 or UDO Section 4.C.2)
36 feet
·        What is the drainage runoff requirement for parking and driveway areas? (COO Section 159.143 or UDO Section 4.D.2)
Drainage of Runoff.  Such parking areas shall be graded and properly drained in such a manner that there will be no free flow of water onto either adjacent property or public sidewalks.  Any runoff generated by such improved areas shall be disposed of in appropriate drainage facilities.
·        Is parking lot lighting required? What is the requirement? (COO Section 159.143 or UDO Section 4.D.4)
  Parking Lot Lighting.  A minimum of one foot-candle of illumination shall be provided throughout the parking lot.  Illumination of off-street parking areas shall be arranged and/or shielded so as not to reflect direct rays of light onto adjacent properties or streets,
·        How many accessible parking spaces are required? (COO Table 11, Section 159.144 or UDO Table 10.0.5)
2
·        Is a loading area required for the library? (COO Section 159.147 or UDO Section 8.A)
Yes
·        How many loading berths are required for the library? (COO Table 13, Section 159.147 or UDO Section 8.B)
1
·        In terms of parking lot landscaping requirements, what class of parking lot is required for the library? (Section 159.184)
Class B. Because the parking lot has 32 parking spaces.
·        Describe the overall interior parking lot landscape requirements.
5%
·        What are the requirements for single row parking landscape islands and peninsulas?
180sq feet in area
·        What are the requirements for double row parking landscape islands and peninsulas?
240sq feet in area
·        Where can one find the perimeter parking lot landscaping requirements? You may need to reference this information later.
Table 12.0.5.D.2
·        What other landscaping requirements are contained in the code of ordinances?
33 plants per 100 linear feet
·        Describe the requirements for trash receptacle enclosures. (Section 159.187)
3 sides inclosed by same building materials and an enclosed gate. has to be 6 feet high or 2 feet above the trash can.